GEO Ground Fluke-1621 Portable Earth Resistance Tester Fluke 1621,Digital Resistance Meters

Feedback Ratings
US $580.00 / Piece |1 Piece (Min. Order)
Quantity:
- + Pieces available
0piecesselected, US $in total
View Details
Shipping:
Please confirm the quantity of the goods.
Overview
Quick Details
Place of Origin:
Guangdong, China (Mainland)
Brand Name:
FLUKE
Model Number:
FLUKE-1621
Display Type:
Digital Only
Measuring Range:
0- 4.00kΩ
Testing Voltage:
0-200V
Accuracy Class:
6% rdg + 5dgt
Operating Temperature:
-10°C to 50°C
Dimensions:
113 x 54 x 216 mm
Battery:
1 LR61 9V
Weight:
850 g
Measuring rate:
2 measurements/second
Warranty:
1 year
OEM/ODM:
No

GEO Ground Fluke-1621 Earth Tester,Portable Earth Resistance Tester Fluke 1621,Digital Resistance Meters

Product Description

The Fluke 1621 is an easy-to-use earth ground tester. For ground resistance testing, the 1621 is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.

General Specifications

Measuring functions

3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage

Intrinsic error

Refers to the reference temperature range and is guaranteed for one year

Measuring rate

2 measurements/second

Battery1

One 9 volt alkaline (LR61)

Battery condition

LO-BAT is displayed if voltage drops below 6.5 V

Voltages

Between jacks H/C2 and E/C1

250 Veff maximum (effective voltage)

Between jacks S/P2 and E/C1

250 Veff maximum

Climatic class

VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87)

Temperature performance2

Working

-10°C to +50°C (+14°F to +122°F)

Operating

0°C to +35°C (+32°F to +95°F)

Storage

-20°C to +60°C (+68°F to +140°F)

Reference

+23°C ±2°C (+73°F ±4°F)

Temperature coefficient

±0.1% of range per degree Kelvin

Safety

IEC/EN 61010-1, 600 V CAT II, pollution degree 2

Dimensions

113 x 54 x 216 mm (4.5 x 2.1 x 8.5 in), including holster

Weight

850 g (1.9 lb), including standard accessories, volume approximately 600 cm3

Electrical Specifications

Maximum deviations

E1Influence factor

Position

E1Deviation influence

0%

E2Influence factor

Supply voltage

E2Deviation influence

0%

E3Influence factor

Temperature E3

E3Deviation influence

2.3%

E4Influence factor

Serial interference voltage (20 V)

E4Deviation influence

0.6%

E5Influence factor

Probe- and auxiliary probe resistance

E5Deviation influence

10%

Test voltage

3.7 kV

Protection type

IP 40; IEC/EN 60529

Electromagnetic compatibility

Emission

IEC/EN 61326 Class B

Immunity

IEC/EN 61326 Class B

RE Resistance measurement

Measuring method

Current-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC/EN 61557–5

Open circuit voltage

23 to 24 V AC

Short circuit current

> 50 mA AC

Measuring frequency

128 Hz

Maximum permissible overload

250 Veff

Measuring time

8 seconds (average from when START is pressed)

Limit input

Tester retains set value even if instrument is turned off  (assuming battery power supply is sufficient)

Automatic changeover of resolution

RH

< 7 kΩ

 

Resolution

0.01 Ω

 

RH

< 50 kΩ

 

Resolution

0.1 Ω

 

RH

> 50 kΩ

 

Resolution

1 Ω

Interference voltage  display DC + AC

Vmax

30 Veff

Common mode rejection

> 80 dB at 50 Hz and 60 Hz

Ri

680 kΩ

Measuring uncertainty

< 10% for pure AC and DC signals

Measuring Range

0.15 Ω to 20 Ω

Resolution

0.01 Ω

Display range

0 to 19.99 Ω

200 Ω

Resolution

0.1 Ω

Display range

20 to 199.9 Ω

2 kΩ

Resolution

1 Ω

Display range

200 to 1999 Ω

Intrinsic Uncertainty

±(6% of measured value + 5D)

Operating uncertainty IEC 615573

±(18% of measured value + 5D)

1. If the tester is not going to be used, or is being stored for a long period, remove the battery and store separately from the tester to avoid damage from battery leakage.
2. The four temperature ranges for the tester exists to satisfy European Standards requirements; the instrument can be used over the full working temperature range by using the temperature coefficient to calculate accuracy at the ambient temperature of use.
3. Covers all deviations caused by influence quantities E1–E5. If the deviation E4 caused by high probe or auxiliary probe resistance is higher than specified flashes. Measured values are outside of the specified operating uncertainty.

Company Information

 

Our Services

 

If you find any problem with the goods within 7 days since you get them, you could return the goods to us and we will resend a good new one to you after we receive the goods.

  • Our warranty for the goods is one year and we always test every product cautiously and strictly before sending them out to our customers.

 Delivery Term

Shipment within 2 days after recceiving the payment for sample or there are in stock, the delivery term is 20-30 days for in bulk or OEM.

 

 Payment Term

  • Western Union
  • Paypal
  • T/T

Why would you choose us?

 

1.We offer factory price products

2.We accept small quantity & wholesale orders (NO MOQ)

3.We keep our stocks available for anytime order

Contact Details:

E-mail:canixie @yehai.net.cn or 18076757614 @163.com

Tel: +86-0755-83766661

Fax:0755-26502620

Mob:+86-18076757614

Skype:cani xie

WhatApp:18076757614

QQ:2053853732

Add:Southeast Of Floor 4, Bldg. 1, Pingshan Minqi Technology Park, Taoyuan St., Nanshan District, Shenzhen, Guangdong, China (Mainland) Subway station :line 5 University Town  Exit C